Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Main subject
Language
Document Type
Year range
1.
Diagnostics (Basel, Switzerland) ; 13(5), 2023.
Article in English | EuropePMC | ID: covidwho-2257240

ABSTRACT

This study aimed to evaluate the performance characteristics of a rapid antigen test developed to detect SARS-CoV-2 (COVID-19), influenza A virus (IAV), and influenza B virus (IBV) (flu) compared with those of the real-time reverse transcription-polymerase chain reaction (rRT-PCR) method. One hundred SARS-CoV-2, one hundred IAV, and twenty-four IBV patients whose diagnoses were confirmed by clinical and laboratory methods were included in the patient group. Seventy-six patients, who were negative for all respiratory tract viruses, were included as the control group. The Panbio™ COVID-19/Flu A&B Rapid Panel test kit was used in the assays. The sensitivity values of the kit were 97.5%, 97.9%, and 33.33% for SARS-CoV-2, IAV, and IBV, respectively, in samples with a viral load below 20 Ct values. The sensitivity values of the kit were 16.7%, 36.5%, and 11.11% for SARS-CoV-2, IAV, and IBV, respectively, in samples with a viral load above 20 Ct. The kit's specificity was 100%. In conclusion, this kit demonstrated high sensitivity to SARS-CoV-2 and IAV for viral loads below 20 Ct values, but the sensitivity values were not compatible with PCR positivity for lower viral loads over 20 Ct values. Rapid antigen tests may be preferred as a routine screening tool in communal environments, especially in symptomatic individuals, when diagnosing SARS-CoV-2, IAV, and IBV with high caution.

2.
Diagnostics (Basel) ; 13(5)2023 Mar 03.
Article in English | MEDLINE | ID: covidwho-2257241

ABSTRACT

This study aimed to evaluate the performance characteristics of a rapid antigen test developed to detect SARS-CoV-2 (COVID-19), influenza A virus (IAV), and influenza B virus (IBV) (flu) compared with those of the real-time reverse transcription-polymerase chain reaction (rRT-PCR) method. One hundred SARS-CoV-2, one hundred IAV, and twenty-four IBV patients whose diagnoses were confirmed by clinical and laboratory methods were included in the patient group. Seventy-six patients, who were negative for all respiratory tract viruses, were included as the control group. The Panbio™ COVID-19/Flu A&B Rapid Panel test kit was used in the assays. The sensitivity values of the kit were 97.5%, 97.9%, and 33.33% for SARS-CoV-2, IAV, and IBV, respectively, in samples with a viral load below 20 Ct values. The sensitivity values of the kit were 16.7%, 36.5%, and 11.11% for SARS-CoV-2, IAV, and IBV, respectively, in samples with a viral load above 20 Ct. The kit's specificity was 100%. In conclusion, this kit demonstrated high sensitivity to SARS-CoV-2 and IAV for viral loads below 20 Ct values, but the sensitivity values were not compatible with PCR positivity for lower viral loads over 20 Ct values. Rapid antigen tests may be preferred as a routine screening tool in communal environments, especially in symptomatic individuals, when diagnosing SARS-CoV-2, IAV, and IBV with high caution.

3.
Clin Lab ; 68(9)2022 Sep 01.
Article in English | MEDLINE | ID: covidwho-2040368

ABSTRACT

BACKGROUND: COVID-19 causes clinical manifestations ranging from asymptomatic infection to multi-organ failure. It is reported that those with severe disease have higher anti-SARS-CoV-2 antibody titers compared to asymptomatic or mild cases. We evaluated the correlation of antibody responses with laboratory and clinical indicators in COVID-19 patients. METHODS: Seventy-nine male and 66 female patients (mean age: 39) with at least one positive SARS-CoV-2 RT-PCR test and SARS-CoV-2 IgG antibody result after acute infection were included. RESULTS: Seventy-six (52%), 45 (31%), and 24 (17%) patients had mild, moderate, and severe clinical findings, respectively. Patients with high body mass index and advanced age had significantly more severe disease (p < 0.001). A significant correlation was found between the increase in lymphopenia, C-reactive protein, ferritin, D-dimer, and lactate dehydrogenase and the severity of clinical findings (p = 0.0001). SARS-CoV-2 IgG antibody test was positive in 128 (88.3%) patients. A significant correlation was found between disease severity and antibody levels in the comparison of all groups (p < 0.001). CONCLUSIONS: Long-term monitoring of immune responses will be required to determine the appropriate time for the administration of new vaccines.


Subject(s)
COVID-19 , Adult , C-Reactive Protein , COVID-19/diagnosis , Female , Ferritins , Humans , Immunoglobulin G , Lactate Dehydrogenases , Male , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL